Ballasted Foundations.
The Ideal Choice for Non-Invasive Installations.

Having a solution that requires no breaking ground is essential. Whether there's an area of archeological interest, underground services, impenetrable ground makeup, land with very low cohesive resistivity or high corrosivity...
Our ballast system is always available to provide the solution.
Using readily available materials including the use of high-density concrete blocks, reclaimed concrete railway sleepers and pre-cast concrete mono-block, the ballast system is easy to install and extremely diverse in its applications.
Ballasted

Name:
Ballasted
Applicable with:
Twin post system
Suitable for:
Sites where breaking ground is not permitted (archaeological or geotechincal)
Installation:
Steel plates weighted with high density concrete blocks. Total weight of blocks to be determined by geotechnical and wind load testing.
Material:
S350, S450 galvanised steel (ZM310, ZM430, ZM620, ZM800). Corrosion protection to be determined from site location and ground investigations.
Dimensions:
Plate size: 960mm x 900mm
Design codes:
Designed in accordance with
BS EN 1991-1-4:2005 +A1:2010. BS EN 1090 &